0.0 / 5.0 - (0 Ratings)

NMV1205SAC

Electronics Part Number

NMV1205SAC-WX
NMV1205SAC

Description

5V 1W DC-DC Converter Miniature Power Supply Module

Inventory

551 Pcs New Original In Stock
Isolated module converter | 5V/200mA, 10.8–13.2V input | Regulated isolated output | Digital logic, microcontrollers
Quantity
Minimum 1

Purchase and inquiry

Quality Assurance

365 - Day Quality Guarantee - Every part fully backed.

90 - Day Refund or Exchange - Defective parts? No hassle.

Limited Stock, Order Now - Get reliable parts without worry.

Global Shipping & Secure Packaging

Worldwide Delivery in 3-5 Business Days

100% ESD Anti-Static Packaging

Real-Time Tracking for Every Order

Secure & Flexible Payment

Credit Card, VISA, MasterCard, PayPal, Western Union, Telegraphic Transfer(T/T) and more

All payments encrypted for security

RFQ (Request for Quotations)

Submit your RFQ directly on the product detail page or the RFQ page.

Our sales team will respond within 24 hours.

Payment method

PayPal (recommended for new customers)

Credit Cards

Wire Transfer (T/T) – Available in USD, EUR, HKD, and other currencies.

Important Notice

You'll receive a confirmation email after submitting an RFQ.

Didn't get it? Check your spam folder and whitelist Info@WINSURE-Electronics.com

Prices and stock may change; we'll reconfirm your order.

Questions? Contact us anytime.

Freight

Basic cost: USD 70.00

Actual cost may vary depending on weight and destination

Shipping method

Shipped from Hong Kong via FedEx/DHL/UPS/TNT

Delivery Time

In-stock items: Ready to ship in 1-2 days

Transit time: 3-5 business days (FedEx/DHL/UPS)

Special requests? Contact us: Info@WINSURE-Electronics.com

Request Quote (Ships tomorrow)
*Quantity
Minimum 1
num_del num_add
(*) (*) is mandatory
We'll get back to you within 24 hours

Technical Specifications

Category DC DC Converters

Manufacturer Murata Power Solutions

Packaging Tube

Operating Temperature -40°C ~ 85°C

Mounting Type Through Hole

Package / Case 7-SIP Module, 4 Leads

Series NMV (1W)

Features -

Base Product Number NMV12

Product Status Active

Type Isolated Module

Number of Outputs 1

Voltage - Input (Min) 10.8V

Voltage - Input (Max) 13.2V

Voltage - Output 1 5V

Voltage - Output 2 -

Voltage - Output 3 -

Current - Output (Max) 200mA

Power (Watts) 1 W

Voltage - Isolation 3 kV

Applications ITE (Commercial)

Efficiency 69%

Size / Dimension 0.77" L x 0.24" W x 0.39" H (19.5mm x 6.0mm x 10.0mm)

Control Features -

Data Sheet Document (D)

Datasheets Download NMV1205SAC Product Specification (PDF)

HTML Datasheet NMV1205SAC-DG

Environmental & Export Classification

RoHS Status ROHS3 Compliant

Moisture Sensitivity Level (MSL) Not Applicable

REACH Status REACH Unaffected

ECCN EAR99

HTSUS 8504.40.9580

Additional Information

Other Names 811-1596-5

Standard Package 25

Reviews

0.0/5.0-(Show up to 5 Ratings)
No reviews yet
Publish Evalution
* Product Rating
(Normal/Preferably/Outstanding, default 5 stars)
★★★★★
★★★★★
*Evalution Message
Please enter your review message.
Please post honest comments and do not post ilegal comments.

Frequently Asked Questions (FAQ)

FAQ Icon

Can the NMV1205SAC be used in a 12V automotive application where input voltage may briefly spike to

The NMV1205SAC has a maximum input voltage rating of 13.2V, making it unsuitable for direct use in automotive environments where load dump transients can exceed 14V. Even brief overvoltage events risk permanent damage to the internal circuitry. To safely use the NMV1205SAC in such applications, you must implement upstream protection—such as a TVS diode (e.g., SMAJ13A) and an LC filter—to clamp the input below 13.2V. Alternatively, consider a wider-input-range isolated converter like the RECOM R-78E5.0-0.5 (4.75–28V input) for robust automotive integration.
FAQ Icon

Is it safe to parallel two NMV1205SAC modules to increase output current beyond 200mA in a space-con

No, paralleling NMV1205SAC modules is not recommended due to lack of current-sharing features and potential imbalance from manufacturing tolerances. Even small differences in output voltage can cause one module to carry most of the load, leading to thermal runaway and premature failure. Instead, select a single higher-current isolated converter such as the Murata NXE1S0505MC (5V/200mA → 5V/300mA) or a non-isolated buck regulator if isolation isn’t critical. If isolation is required and higher power is needed, redesign with a module rated for the total load from the start.
FAQ Icon

Can the NMV1205SAC replace a legacy CUI PDQ1-S12-S5-S in a medical device requiring 3 kV isolation a

While both the NMV1205SAC and CUI PDQ1-S12-S5-S provide 5V/200mA output and 3 kV isolation, direct replacement requires verification of pin compatibility, thermal performance, and regulatory certifications. The NMV1205SAC uses a 7-SIP package with different lead spacing than the PDQ1’s DIP-style footprint, so PCB layout changes may be needed. Additionally, confirm that the NMV1205SAC meets your medical application’s leakage current and safety standards (e.g., IEC 60601), as commercial ITE-rated parts may lack necessary medical certifications. Always validate EMI and isolation integrity in your final system.
FAQ Icon

What are the thermal risks of operating the NMV1205SAC at full 1W load in an enclosed industrial con

Operating the NMV1205SAC at full load in a 70°C ambient environment pushes it near its operational limit, as its maximum case temperature is typically ~100°C and efficiency is only 69%. This results in ~0.45W of internal dissipation, which—without adequate airflow or heatsinking—can cause junction temperatures to exceed safe margins, reducing lifespan and reliability. Mitigate this by derating the output current (e.g., limit to ~150mA), adding venting or forced airflow, or selecting a higher-efficiency alternative like the TRACO TEN1-0512 (80% efficiency). Always measure actual case temperature under worst-case conditions during prototyping.
FAQ Icon

How does the NMV1205SAC compare to the RECOM R-62050 in terms of long-term reliability for remote Io

The NMV1205SAC and RECOM R-62050 both offer 5V/200mA isolated outputs from 12V inputs, but the R-62050 has superior efficiency (~85% vs. 69%) and lower no-load quiescent current (<10mA vs. ~20–30mA typical for NMV series), making it better suited for battery-powered IoT nodes where energy conservation is critical. Additionally, RECOM provides detailed MTBF data and wider temperature characterization, supporting more reliable lifetime predictions. For remote deployments where maintenance is costly, the R-62050’s lower heat generation and higher efficiency reduce thermal stress and extend operational life—making it a lower-risk choice despite the NMV1205SAC’s compact size and lower upfront cost.
FAQ Icon

Can the NMV1205SAC be used in a 12V automotive application where input voltage may briefly spike to

The NMV1205SAC has a maximum input voltage rating of 13.2V, making it unsuitable for direct use in automotive environments where load dump transients can exceed 14V. Even brief overvoltage events risk permanent damage to the internal circuitry. To safely use the NMV1205SAC in such applications, you must implement upstream protection—such as a TVS diode (e.g., SMAJ13A) and an LC filter—to clamp the input below 13.2V. Alternatively, consider a wider-input-range isolated converter like the RECOM R-78E5.0-0.5 (4.75–28V input) for robust automotive integration.
FAQ Icon

Is it safe to parallel two NMV1205SAC modules to increase output current beyond 200mA in a space-con

No, paralleling NMV1205SAC modules is not recommended due to lack of current-sharing features and potential imbalance from manufacturing tolerances. Even small differences in output voltage can cause one module to carry most of the load, leading to thermal runaway and premature failure. Instead, select a single higher-current isolated converter such as the Murata NXE1S0505MC (5V/200mA → 5V/300mA) or a non-isolated buck regulator if isolation isn’t critical. If isolation is required and higher power is needed, redesign with a module rated for the total load from the start.
FAQ Icon

Can the NMV1205SAC replace a legacy CUI PDQ1-S12-S5-S in a medical device requiring 3 kV isolation a

While both the NMV1205SAC and CUI PDQ1-S12-S5-S provide 5V/200mA output and 3 kV isolation, direct replacement requires verification of pin compatibility, thermal performance, and regulatory certifications. The NMV1205SAC uses a 7-SIP package with different lead spacing than the PDQ1’s DIP-style footprint, so PCB layout changes may be needed. Additionally, confirm that the NMV1205SAC meets your medical application’s leakage current and safety standards (e.g., IEC 60601), as commercial ITE-rated parts may lack necessary medical certifications. Always validate EMI and isolation integrity in your final system.
FAQ Icon

What are the thermal risks of operating the NMV1205SAC at full 1W load in an enclosed industrial con

Operating the NMV1205SAC at full load in a 70°C ambient environment pushes it near its operational limit, as its maximum case temperature is typically ~100°C and efficiency is only 69%. This results in ~0.45W of internal dissipation, which—without adequate airflow or heatsinking—can cause junction temperatures to exceed safe margins, reducing lifespan and reliability. Mitigate this by derating the output current (e.g., limit to ~150mA), adding venting or forced airflow, or selecting a higher-efficiency alternative like the TRACO TEN1-0512 (80% efficiency). Always measure actual case temperature under worst-case conditions during prototyping.
FAQ Icon

How does the NMV1205SAC compare to the RECOM R-62050 in terms of long-term reliability for remote Io

The NMV1205SAC and RECOM R-62050 both offer 5V/200mA isolated outputs from 12V inputs, but the R-62050 has superior efficiency (~85% vs. 69%) and lower no-load quiescent current (<10mA vs. ~20–30mA typical for NMV series), making it better suited for battery-powered IoT nodes where energy conservation is critical. Additionally, RECOM provides detailed MTBF data and wider temperature characterization, supporting more reliable lifetime predictions. For remote deployments where maintenance is costly, the R-62050’s lower heat generation and higher efficiency reduce thermal stress and extend operational life—making it a lower-risk choice despite the NMV1205SAC’s compact size and lower upfront cost.

Quality Assurance (QC)

WINSURE ensures the quality and authenticity of every electronic component through professional inspections and batch sampling, guaranteeing reliable sourcing, stable performance, and compliance with technical specifications, helping customers reduce supply chain risks and confidently use components in production.

Quality Assurance
Counterfeit and defect prevention

Counterfeit and defect prevention

Visual and packaging inspection

Electrical performance verification

Electrical performance verification

Life and reliability evaluation

Life and reliability evaluation

WINSURE Certification
ISO 209001_2015
ISO 209001_2015
ISO 14001_2015
ISO 2014001_2015
ISO 45001_2018
ISO 2045001_2018
DUNS REGISTERED
DUNS REGISTERED
Companines Registry
Companines Registry
ASA Certificate
ASA Certificate
UKAS
UKAS
ESD Certificate
ESD Certificate
Blogs & Posts
whatsapp-icons Chat online
RFQ List ({0} Items)

You can add multiple products here.

  • It is empty.
del Clear All Products
Compare List ({0} Items)

You can add multiple products here.

  • It is empty.
del Clear All Products