0.0 / 5.0 - (0 Ratings)

NMV1209DAC

Electronics Part Number

NMV1209DAC-WX
NMV1209DAC

Description

DC-DC Converter, 9V Output, 1W

Inventory

184 Pcs New Original In Stock
-
Quantity
Minimum 1

Purchase and inquiry

Quality Assurance

365 - Day Quality Guarantee - Every part fully backed.

90 - Day Refund or Exchange - Defective parts? No hassle.

Limited Stock, Order Now - Get reliable parts without worry.

Global Shipping & Secure Packaging

Worldwide Delivery in 3-5 Business Days

100% ESD Anti-Static Packaging

Real-Time Tracking for Every Order

Secure & Flexible Payment

Credit Card, VISA, MasterCard, PayPal, Western Union, Telegraphic Transfer(T/T) and more

All payments encrypted for security

RFQ (Request for Quotations)

Submit your RFQ directly on the product detail page or the RFQ page.

Our sales team will respond within 24 hours.

Payment method

PayPal (recommended for new customers)

Credit Cards

Wire Transfer (T/T) – Available in USD, EUR, HKD, and other currencies.

Important Notice

You'll receive a confirmation email after submitting an RFQ.

Didn't get it? Check your spam folder and whitelist Info@WINSURE-Electronics.com

Prices and stock may change; we'll reconfirm your order.

Questions? Contact us anytime.

Freight

Basic cost: USD 70.00

Actual cost may vary depending on weight and destination

Shipping method

Shipped from Hong Kong via FedEx/DHL/UPS/TNT

Delivery Time

In-stock items: Ready to ship in 1-2 days

Transit time: 3-5 business days (FedEx/DHL/UPS)

Special requests? Contact us: Info@WINSURE-Electronics.com

Request Quote (Ships tomorrow)
*Quantity
Minimum 1
num_del num_add
(*) (*) is mandatory
We'll get back to you within 24 hours

Technical Specifications

Category DC DC Converters

Manufacturer Murata Power Solutions

Packaging -

Operating Temperature -40°C ~ 85°C

Mounting Type Through Hole

Package / Case 14-DIP Module, 6 Leads

Series NMV (1W)

Features -

Base Product Number NMV12

Product Status Active

Type Isolated Module

Number of Outputs 1

Voltage - Input (Min) 10.8V

Voltage - Input (Max) 13.2V

Voltage - Output 1 9V

Voltage - Output 2 -

Voltage - Output 3 -

Current - Output (Max) 111mA

Power (Watts) 1 W

Voltage - Isolation 3 kV

Applications ITE (Commercial)

Efficiency 74%

Size / Dimension 0.77" L x 0.39" W x 0.27" H (19.6mm x 9.9mm x 6.9mm)

Control Features -

Data Sheet Document (D)

Datasheets Download NMV1209DAC Product Specification (PDF)

HTML Datasheet NMV1209DAC-DG

Environmental & Export Classification

RoHS Status ROHS3 Compliant

Moisture Sensitivity Level (MSL) Not Applicable

REACH Status REACH Unaffected

ECCN EAR99

HTSUS 8504.40.9580

Additional Information

Standard Package 25

Reviews

0.0/5.0-(Show up to 5 Ratings)
No reviews yet
Publish Evalution
* Product Rating
(Normal/Preferably/Outstanding, default 5 stars)
★★★★★
★★★★★
*Evalution Message
Please enter your review message.
Please post honest comments and do not post ilegal comments.

Frequently Asked Questions (FAQ)

FAQ Icon

Can the NMV1209DAC be used in parallel to increase output current in high-reliability industrial app

No, the NMV1209DAC is not designed for parallel operation. Attempting to parallel multiple units can lead to current imbalance, instability, and potential damage due to slight differences in startup timing and output regulation. For higher output current, consider using a single higher-power isolated converter such as the Murata NMF1214SCA (2W) or re-evaluating the system architecture with a non-isolated point-of-load regulator downstream of the NMV1209DAC to scale current safely while maintaining isolation integrity.
FAQ Icon

What are the key design-in risks when replacing the NMV1209DAC with the comparable Traco Power TML1-

When replacing the NMV1209DAC with the Traco TML1-W1209DC/FT, key risks include differences in footprint (TML1 uses a similar but not identical 14-DIP), thermal performance under full load, and slight variations in input voltage startup thresholds. The NMV1209DAC has a tighter input range (10.8–13.2V) compared to the TML1's wider 9–18V range—this can expose design flaws if upstream supply dips below 10.8V were previously masked. Always verify turn-on behavior under brownout conditions and confirm creepage/clearance is maintained for 3 kV isolation in your PCB layout.
FAQ Icon

How does the 74% efficiency of the NMV1209DAC impact thermal performance in enclosed spaces at 85°C

With only 74% efficiency, the NMV1209DAC dissipates approximately 260 mW internally at full 1W load. In enclosed or poorly ventilated systems operating at 85°C ambient, this self-heating can push internal component temperatures close to or beyond safety margins, risking premature failure. To mitigate thermal stress, limit continuous loading to 70–80% of max rating (≤800 mW), ensure adequate PCB copper for heatsinking via the through-hole pins, and avoid placing near other heat-generating components to preserve reliability over the product lifetime.
FAQ Icon

Is the NMV1209DAC suitable for signal isolation and level-shifting in precision analog sensor interf

While the NMV1209DAC provides 3 kV isolation, it is a power conversion module with unregulated output and potential for switching noise, making it unsuitable for direct use in precision analog signal paths. However, it can power isolated signal chains—like using a separate low-noise LDO (e.g., Torex XC6206P092MR-G) post-regulating the 9V output—enabling clean rail generation for analog front-ends. Use proper filtering (π-filter with ferrite bead) and ground separation to prevent noise coupling into sensitive circuits when integrating the NMV1209DAC in mixed-signal designs.
FAQ Icon

What layout and creepage best practices should be followed to maintain 3 kV isolation with the NMV12

To maintain rated 3 kV isolation in high-humidity or polluted environments with the NMV1209DAC, ensure creepage distances exceed 8 mm between input and output circuits (IPC-2221B guidelines for 3 kV), use slotting under the 6-lead DIP module to increase path length, and apply conformal coating to prevent moisture tracking. Avoid routing high-voltage traces under the module body, and separate input/output grounds with a moat that aligns with the internal isolation barrier. These steps preserve long-term reliability in demanding commercial ITE applications.
FAQ Icon

Can the NMV1209DAC be used in parallel to increase output current in high-reliability industrial app

No, the NMV1209DAC is not designed for parallel operation. Attempting to parallel multiple units can lead to current imbalance, instability, and potential damage due to slight differences in startup timing and output regulation. For higher output current, consider using a single higher-power isolated converter such as the Murata NMF1214SCA (2W) or re-evaluating the system architecture with a non-isolated point-of-load regulator downstream of the NMV1209DAC to scale current safely while maintaining isolation integrity.
FAQ Icon

What are the key design-in risks when replacing the NMV1209DAC with the comparable Traco Power TML1-

When replacing the NMV1209DAC with the Traco TML1-W1209DC/FT, key risks include differences in footprint (TML1 uses a similar but not identical 14-DIP), thermal performance under full load, and slight variations in input voltage startup thresholds. The NMV1209DAC has a tighter input range (10.8–13.2V) compared to the TML1's wider 9–18V range—this can expose design flaws if upstream supply dips below 10.8V were previously masked. Always verify turn-on behavior under brownout conditions and confirm creepage/clearance is maintained for 3 kV isolation in your PCB layout.
FAQ Icon

How does the 74% efficiency of the NMV1209DAC impact thermal performance in enclosed spaces at 85°C

With only 74% efficiency, the NMV1209DAC dissipates approximately 260 mW internally at full 1W load. In enclosed or poorly ventilated systems operating at 85°C ambient, this self-heating can push internal component temperatures close to or beyond safety margins, risking premature failure. To mitigate thermal stress, limit continuous loading to 70–80% of max rating (≤800 mW), ensure adequate PCB copper for heatsinking via the through-hole pins, and avoid placing near other heat-generating components to preserve reliability over the product lifetime.
FAQ Icon

Is the NMV1209DAC suitable for signal isolation and level-shifting in precision analog sensor interf

While the NMV1209DAC provides 3 kV isolation, it is a power conversion module with unregulated output and potential for switching noise, making it unsuitable for direct use in precision analog signal paths. However, it can power isolated signal chains—like using a separate low-noise LDO (e.g., Torex XC6206P092MR-G) post-regulating the 9V output—enabling clean rail generation for analog front-ends. Use proper filtering (π-filter with ferrite bead) and ground separation to prevent noise coupling into sensitive circuits when integrating the NMV1209DAC in mixed-signal designs.
FAQ Icon

What layout and creepage best practices should be followed to maintain 3 kV isolation with the NMV12

To maintain rated 3 kV isolation in high-humidity or polluted environments with the NMV1209DAC, ensure creepage distances exceed 8 mm between input and output circuits (IPC-2221B guidelines for 3 kV), use slotting under the 6-lead DIP module to increase path length, and apply conformal coating to prevent moisture tracking. Avoid routing high-voltage traces under the module body, and separate input/output grounds with a moat that aligns with the internal isolation barrier. These steps preserve long-term reliability in demanding commercial ITE applications.

Quality Assurance (QC)

WINSURE ensures the quality and authenticity of every electronic component through professional inspections and batch sampling, guaranteeing reliable sourcing, stable performance, and compliance with technical specifications, helping customers reduce supply chain risks and confidently use components in production.

Quality Assurance
Counterfeit and defect prevention

Counterfeit and defect prevention

Visual and packaging inspection

Electrical performance verification

Electrical performance verification

Life and reliability evaluation

Life and reliability evaluation

WINSURE Certification
ISO 209001_2015
ISO 209001_2015
ISO 14001_2015
ISO 2014001_2015
ISO 45001_2018
ISO 2045001_2018
DUNS REGISTERED
DUNS REGISTERED
Companines Registry
Companines Registry
ASA Certificate
ASA Certificate
UKAS
UKAS
ESD Certificate
ESD Certificate
Blogs & Posts
whatsapp-icons Chat online
RFQ List ({0} Items)

You can add multiple products here.

  • It is empty.
del Clear All Products
Compare List ({0} Items)

You can add multiple products here.

  • It is empty.
del Clear All Products