0.0 / 5.0 - (0 Ratings)

NMV0515SAC

Electronics Part Number

NMV0515SAC-WX
NMV0515SAC

Description

DC-DC Converter 15V 1W Single Output Miniature Module

Inventory

964 Pcs New Original In Stock
Isolated DC-DC module | 15V/67mA, 4.5–5.5V input | Compact reliable power conversion | Analog front-ends, isolated data links
Quantity
Minimum 1

Purchase and inquiry

Quality Assurance

365 - Day Quality Guarantee - Every part fully backed.

90 - Day Refund or Exchange - Defective parts? No hassle.

Limited Stock, Order Now - Get reliable parts without worry.

Global Shipping & Secure Packaging

Worldwide Delivery in 3-5 Business Days

100% ESD Anti-Static Packaging

Real-Time Tracking for Every Order

Secure & Flexible Payment

Credit Card, VISA, MasterCard, PayPal, Western Union, Telegraphic Transfer(T/T) and more

All payments encrypted for security

RFQ (Request for Quotations)

Submit your RFQ directly on the product detail page or the RFQ page.

Our sales team will respond within 24 hours.

Payment method

PayPal (recommended for new customers)

Credit Cards

Wire Transfer (T/T) – Available in USD, EUR, HKD, and other currencies.

Important Notice

You'll receive a confirmation email after submitting an RFQ.

Didn't get it? Check your spam folder and whitelist Info@WINSURE-Electronics.com

Prices and stock may change; we'll reconfirm your order.

Questions? Contact us anytime.

Freight

Basic cost: USD 70.00

Actual cost may vary depending on weight and destination

Shipping method

Shipped from Hong Kong via FedEx/DHL/UPS/TNT

Delivery Time

In-stock items: Ready to ship in 1-2 days

Transit time: 3-5 business days (FedEx/DHL/UPS)

Special requests? Contact us: Info@WINSURE-Electronics.com

Request Quote (Ships tomorrow)
*Quantity
Minimum 1
num_del num_add
(*) (*) is mandatory
We'll get back to you within 24 hours

Technical Specifications

Category DC DC Converters

Manufacturer Murata Power Solutions

Packaging Tube

Operating Temperature -40°C ~ 85°C

Mounting Type Through Hole

Package / Case 7-SIP Module, 4 Leads

Series NMV (1W)

Features -

Base Product Number NMV05

Product Status Active

Type Isolated Module

Number of Outputs 1

Voltage - Input (Min) 4.5V

Voltage - Input (Max) 5.5V

Voltage - Output 1 15V

Voltage - Output 2 -

Voltage - Output 3 -

Current - Output (Max) 67mA

Power (Watts) 1 W

Voltage - Isolation 3 kV

Applications ITE (Commercial)

Efficiency 78%

Size / Dimension 0.77" L x 0.24" W x 0.39" H (19.5mm x 6.0mm x 10.0mm)

Control Features -

Data Sheet Document (D)

Datasheets Download NMV0515SAC Product Specification (PDF)

HTML Datasheet NMV0515SAC-DG

Environmental & Export Classification

RoHS Status ROHS3 Compliant

Moisture Sensitivity Level (MSL) Not Applicable

REACH Status REACH Unaffected

ECCN EAR99

HTSUS 8504.40.9580

Additional Information

Other Names 811-1593-5

Standard Package 25

Reviews

0.0/5.0-(Show up to 5 Ratings)
No reviews yet
Publish Evalution
* Product Rating
(Normal/Preferably/Outstanding, default 5 stars)
★★★★★
★★★★★
*Evalution Message
Please enter your review message.
Please post honest comments and do not post ilegal comments.

Frequently Asked Questions (FAQ)

FAQ Icon

Can the NMV0515SAC safely power a 15V analog front-end circuit in a noisy industrial environment, an

Yes, the NMV0515SAC can power sensitive 15V analog circuits in industrial settings due to its reinforced 3 kV isolation, but proper PCB layout is critical. Maintain at least 8 mm creepage distance between primary (input) and secondary (output) sides, avoid routing high-speed or high-current traces across the isolation barrier, and use a solid ground plane on the output side only—do not connect input and output grounds. Place decoupling capacitors (100 nF ceramic + 10 µF tantalum) close to the load to suppress high-frequency noise that could bypass isolation through parasitic coupling. Without these mitigations, conducted emissions or ground loops may degrade SNR despite the isolation rating.
FAQ Icon

What are the key reliability risks when using the NMV0515SAC in an outdoor enclosure exposed to temp

While the NMV0515SAC’s -40°C to +85°C range covers your thermal profile, repeated thermal cycling induces mechanical stress on the through-hole leads and internal bond wires, potentially leading to early fatigue failure—especially if the PCB lacks strain relief or is mounted rigidly. Derate output power by 20% above +70°C ambient to avoid exceeding internal junction limits, as efficiency drops near the upper end of the range. Also ensure adequate airflow; stagnant air in sealed enclosures can create localized hot spots. For long-term reliability, consider conformal coating if humidity is present, and validate lifetime under actual cycle conditions via accelerated testing.
FAQ Icon

Can I replace a legacy RECOM R-78B15-0.5 with the NMV0515SAC in an existing 5V-to-15V design without

No—the NMV0515SAC is not a drop-in replacement for the RECOM R-78B15-0.5 due to fundamental topology differences. The R-78B15-0.5 is a non-isolated switching regulator with a 3-pin SIP footprint, while the NMV0515SAC is an isolated 7-SIP module requiring separate input/output grounds and offering no feedback pin. Attempting direct substitution will likely result in incorrect grounding, failed isolation, or damage. If isolation isn’t needed, stick with non-isolated alternatives like the R-78B15-0.5. If isolation is required, redesign the layout to accommodate the NMV0515SAC’s pinout and grounding scheme, and verify load regulation under dynamic conditions.
FAQ Icon

How does the NMV0515SAC’s 78% efficiency impact thermal management in a compact, sealed IoT node dra

At 50 mA output (0.75 W), the NMV0515SAC dissipates approximately 0.21 W as heat (P_loss = P_out × (1/η – 1)). In a sealed IoT enclosure with limited convection, this can raise internal temperatures significantly—especially if other components contribute heat. Use thermal vias under the module (if PCB allows) and ensure the 7-SIP leads act as heat paths to the board. Monitor case temperature; sustained operation above 80°C may accelerate aging. For tighter thermal budgets, consider lower-power alternatives or active cooling. Never rely solely on datasheet efficiency without validating thermal rise in your specific enclosure geometry.
FAQ Icon

Is the NMV0515SAC suitable for floating sensor applications where the 15V output must remain ungroun

Yes, the NMV0515SAC supports floating outputs due to its galvanic isolation, making it ideal for floating sensor biasing (e.g., strain gauges or pH probes). However, avoid inadvertently grounding the output through probe grounds, cable shields, or downstream circuitry—this defeats isolation and can create ground loops or safety hazards. Use differential signaling on the sensor side and ensure all connected equipment respects the floating nature. Also, limit output capacitance to <100 µF to prevent inrush currents during startup that could stress internal components. Always verify isolation integrity with a hipot test (e.g., 2.5 kV AC for 60 sec) during production to catch assembly defects.
FAQ Icon

Can the NMV0515SAC safely power a 15V analog front-end circuit in a noisy industrial environment, an

Yes, the NMV0515SAC can power sensitive 15V analog circuits in industrial settings due to its reinforced 3 kV isolation, but proper PCB layout is critical. Maintain at least 8 mm creepage distance between primary (input) and secondary (output) sides, avoid routing high-speed or high-current traces across the isolation barrier, and use a solid ground plane on the output side only—do not connect input and output grounds. Place decoupling capacitors (100 nF ceramic + 10 µF tantalum) close to the load to suppress high-frequency noise that could bypass isolation through parasitic coupling. Without these mitigations, conducted emissions or ground loops may degrade SNR despite the isolation rating.
FAQ Icon

What are the key reliability risks when using the NMV0515SAC in an outdoor enclosure exposed to temp

While the NMV0515SAC’s -40°C to +85°C range covers your thermal profile, repeated thermal cycling induces mechanical stress on the through-hole leads and internal bond wires, potentially leading to early fatigue failure—especially if the PCB lacks strain relief or is mounted rigidly. Derate output power by 20% above +70°C ambient to avoid exceeding internal junction limits, as efficiency drops near the upper end of the range. Also ensure adequate airflow; stagnant air in sealed enclosures can create localized hot spots. For long-term reliability, consider conformal coating if humidity is present, and validate lifetime under actual cycle conditions via accelerated testing.
FAQ Icon

Can I replace a legacy RECOM R-78B15-0.5 with the NMV0515SAC in an existing 5V-to-15V design without

No—the NMV0515SAC is not a drop-in replacement for the RECOM R-78B15-0.5 due to fundamental topology differences. The R-78B15-0.5 is a non-isolated switching regulator with a 3-pin SIP footprint, while the NMV0515SAC is an isolated 7-SIP module requiring separate input/output grounds and offering no feedback pin. Attempting direct substitution will likely result in incorrect grounding, failed isolation, or damage. If isolation isn’t needed, stick with non-isolated alternatives like the R-78B15-0.5. If isolation is required, redesign the layout to accommodate the NMV0515SAC’s pinout and grounding scheme, and verify load regulation under dynamic conditions.
FAQ Icon

How does the NMV0515SAC’s 78% efficiency impact thermal management in a compact, sealed IoT node dra

At 50 mA output (0.75 W), the NMV0515SAC dissipates approximately 0.21 W as heat (P_loss = P_out × (1/η – 1)). In a sealed IoT enclosure with limited convection, this can raise internal temperatures significantly—especially if other components contribute heat. Use thermal vias under the module (if PCB allows) and ensure the 7-SIP leads act as heat paths to the board. Monitor case temperature; sustained operation above 80°C may accelerate aging. For tighter thermal budgets, consider lower-power alternatives or active cooling. Never rely solely on datasheet efficiency without validating thermal rise in your specific enclosure geometry.
FAQ Icon

Is the NMV0515SAC suitable for floating sensor applications where the 15V output must remain ungroun

Yes, the NMV0515SAC supports floating outputs due to its galvanic isolation, making it ideal for floating sensor biasing (e.g., strain gauges or pH probes). However, avoid inadvertently grounding the output through probe grounds, cable shields, or downstream circuitry—this defeats isolation and can create ground loops or safety hazards. Use differential signaling on the sensor side and ensure all connected equipment respects the floating nature. Also, limit output capacitance to <100 µF to prevent inrush currents during startup that could stress internal components. Always verify isolation integrity with a hipot test (e.g., 2.5 kV AC for 60 sec) during production to catch assembly defects.

Quality Assurance (QC)

WINSURE ensures the quality and authenticity of every electronic component through professional inspections and batch sampling, guaranteeing reliable sourcing, stable performance, and compliance with technical specifications, helping customers reduce supply chain risks and confidently use components in production.

Quality Assurance
Counterfeit and defect prevention

Counterfeit and defect prevention

Visual and packaging inspection

Electrical performance verification

Electrical performance verification

Life and reliability evaluation

Life and reliability evaluation

WINSURE Certification
ISO 209001_2015
ISO 209001_2015
ISO 14001_2015
ISO 2014001_2015
ISO 45001_2018
ISO 2045001_2018
DUNS REGISTERED
DUNS REGISTERED
Companines Registry
Companines Registry
ASA Certificate
ASA Certificate
UKAS
UKAS
ESD Certificate
ESD Certificate
Blogs & Posts
whatsapp-icons Chat online
RFQ List ({0} Items)

You can add multiple products here.

  • It is empty.
del Clear All Products
Compare List ({0} Items)

You can add multiple products here.

  • It is empty.
del Clear All Products