0.0 / 5.0 - (0 Ratings)

LTC7860IMSE#TRPBF

Electronics Part Number

LTC7860IMSE#TRPBF-WX

Manufacturer

Littelfuse
LTC7860IMSE#TRPBF

Description

High Efficiency Switching Surge Suppressor

Inventory

598 Pcs New Original In Stock
Robust circuit protection elements; limit fault currents and suppress dangerous spikes to ensure safe operation of downstream electronics.
Quantity
Minimum 1

Purchase and inquiry

Quality Assurance

365 - Day Quality Guarantee - Every part fully backed.

90 - Day Refund or Exchange - Defective parts? No hassle.

Limited Stock, Order Now - Get reliable parts without worry.

Global Shipping & Secure Packaging

Worldwide Delivery in 3-5 Business Days

100% ESD Anti-Static Packaging

Real-Time Tracking for Every Order

Secure & Flexible Payment

Credit Card, VISA, MasterCard, PayPal, Western Union, Telegraphic Transfer(T/T) and more

All payments encrypted for security

RFQ (Request for Quotations)

Submit your RFQ directly on the product detail page or the RFQ page.

Our sales team will respond within 24 hours.

Payment method

PayPal (recommended for new customers)

Credit Cards

Wire Transfer (T/T) – Available in USD, EUR, HKD, and other currencies.

Important Notice

You'll receive a confirmation email after submitting an RFQ.

Didn't get it? Check your spam folder and whitelist Info@WINSURE-Electronics.com

Prices and stock may change; we'll reconfirm your order.

Questions? Contact us anytime.

Freight

Basic cost: USD 70.00

Actual cost may vary depending on weight and destination

Shipping method

Shipped from Hong Kong via FedEx/DHL/UPS/TNT

Delivery Time

In-stock items: Ready to ship in 1-2 days

Transit time: 3-5 business days (FedEx/DHL/UPS)

Special requests? Contact us: Info@WINSURE-Electronics.com

Request Quote (Ships tomorrow)
*Quantity
Minimum 1
num_del num_add
(*) (*) is mandatory
We'll get back to you within 24 hours

Technical Specifications

Category Transient Voltage Suppressors (TVS), Thyristors

Manufacturer Littelfuse

Packaging Tape & Reel (TR)

Mounting Type Surface Mount

Package / Case 6-SMD, Gull Wing

Series SIDACtor®

Product Status Active

Capacitance 25pF, 35pF

Supplier Device Package Modified MS-013

Voltage - Off State 270V

Current - Hold (Ih) 150 mA

Current - Peak Pulse (10/1000µs) 100 A

Voltage - Breakover 350V

Voltage - On State 8 V

Current - Peak Pulse (8/20µs) 400 A

Number of Elements 6

Data Sheet Document (D)

Datasheets Download P3206UCLRP Product Specification (PDF)

HTML Datasheet P3206UCLRP-DG

Environmental & Export Classification

RoHS Status ROHS3 Compliant

Moisture Sensitivity Level (MSL) 1 (Unlimited)

REACH Status REACH Unaffected

ECCN EAR99

HTSUS 8541.30.0080

Additional Information

Other Names P3206UCL -P3206UCLRP

Standard Package 1,500

Reviews

0.0/5.0-(Show up to 5 Ratings)
No reviews yet
Publish Evalution
* Product Rating
(Normal/Preferably/Outstanding, default 5 stars)
★★★★★
★★★★★
*Evalution Message
Please enter your review message.
Please post honest comments and do not post ilegal comments.

Frequently Asked Questions (FAQ)

FAQ Icon

When designing in the P3206UCLRP SIDACtor® for surge protection in a 240V AC line, how can I ensure

To avoid nuisance tripping of the P3206UCLRP in 240V AC applications, ensure the peak normal operating voltage stays safely below the 350V breakover threshold. Account for line variations—240V AC has a peak of ~340V, leaving only a 10V margin. Design with derating: consider worst-case tolerances (±10%), temperature effects, and transient glitches. Use input filtering or a small series impedance to suppress fast spikes below IEC 61000-4-5 levels. Also verify that the hold current (Ih = 150 mA) is higher than the normal circuit current, so the device resets properly after a surge event. Monitor thermal performance under repeated surges to maintain reliability.
FAQ Icon

Can the P3206UCLRP replace the Bourns TBU-CA065-200-WH1 in a high-speed data line protection circuit

The P3206UCLRP is a TVS thyristor with crowbar action, while the Bourns TBU-CA065-200-WH1 is a bidirectional overcurrent protector (not a voltage suppressor), so direct replacement is not advisable. The P3206UCLRP clamps overvoltage by shorting events via low on-state voltage (8V), but requires external current limiting and may latch up. In data line protection, this could disrupt signal integrity or cause system lockup if not paired with fusing or self-resetting protection. Use the P3206UCLRP only when crowbar action is part of a coordinated protection scheme; for standalone data line isolation, consider transient blocking units like the TBU series in combination with lower-capacitance TVS diodes.
FAQ Icon

How does the 25pF to 35pF capacitance range of the P3206UCLRP affect signal integrity in multi-chann

With a capacitance range of 25pF to 35pF per device, the P3206UCLRP can introduce signal attenuation and skew in high-frequency telecom lines (e.g., xDSL, T1/E1). For multi-channel systems, cumulative parasitic capacitance can degrade crosstalk and rise/fall times. To mitigate, isolate the P3206UCLRP behind series current-limiting resistors or use it only on primary protection stages, not directly on high-speed data lines. Consider splitting protection functions: use low-capacitance TVS diodes (<5pF) for signal lines and reserve the P3206UCLRP for power or low-speed interface rails where crowbar action is acceptable. Always verify eye diagram margins post-layout with the device installed.
FAQ Icon

What are the PCB layout best practices when integrating the P3206UCLRP in surface-mount surge protec

To safely route 400A 8/20µs surge currents in the P3206UCLRP, use wide, short traces (>2mm width or filled polygons) with minimal inductance between the device and threat entry point (e.g., connector). Avoid sharp bends; use curved or mitered corners. Connect the device to a robust ground plane using multiple vias near the pins to reduce thermal and mechanical stress. Place the P3206UCLRP at the point of entry, before any filtering or protection stages, to prevent energy from propagating inward. Use thermal relief pads only if necessary for assembly, but minimize them to maintain heat dissipation. Simulate current density in layout tools to avoid hotspots under repeated surge events.
FAQ Icon

What reliability risks should be considered when using the P3206UCLRP in industrial environments pro

The P3206UCLRP is rated for 100A peak pulse current under 10/1000µs waveform, so operation near 75A repeatedly pushes it close to its limit. Industrial environments with frequent surges risk cumulative degradation due to thermal stress, even if individual events are within spec. Ensure the device has adequate PCB copper for heat dissipation and monitor junction temperature rise. Implement upstream coordination—use gas discharge tubes (GDTs) or series impedance to shunt bulk energy, reserving the P3206UCLRP for residual protection. Verify performance over lifecycle testing simulating real-world surge frequency. Also, validate that the 150mA hold current can be reliably interrupted by the system’s power circuitry to ensure turn-off after triggering.
FAQ Icon

When designing in the P3206UCLRP SIDACtor® for surge protection in a 240V AC line, how can I ensure

To avoid nuisance tripping of the P3206UCLRP in 240V AC applications, ensure the peak normal operating voltage stays safely below the 350V breakover threshold. Account for line variations—240V AC has a peak of ~340V, leaving only a 10V margin. Design with derating: consider worst-case tolerances (±10%), temperature effects, and transient glitches. Use input filtering or a small series impedance to suppress fast spikes below IEC 61000-4-5 levels. Also verify that the hold current (Ih = 150 mA) is higher than the normal circuit current, so the device resets properly after a surge event. Monitor thermal performance under repeated surges to maintain reliability.
FAQ Icon

Can the P3206UCLRP replace the Bourns TBU-CA065-200-WH1 in a high-speed data line protection circuit

The P3206UCLRP is a TVS thyristor with crowbar action, while the Bourns TBU-CA065-200-WH1 is a bidirectional overcurrent protector (not a voltage suppressor), so direct replacement is not advisable. The P3206UCLRP clamps overvoltage by shorting events via low on-state voltage (8V), but requires external current limiting and may latch up. In data line protection, this could disrupt signal integrity or cause system lockup if not paired with fusing or self-resetting protection. Use the P3206UCLRP only when crowbar action is part of a coordinated protection scheme; for standalone data line isolation, consider transient blocking units like the TBU series in combination with lower-capacitance TVS diodes.
FAQ Icon

How does the 25pF to 35pF capacitance range of the P3206UCLRP affect signal integrity in multi-chann

With a capacitance range of 25pF to 35pF per device, the P3206UCLRP can introduce signal attenuation and skew in high-frequency telecom lines (e.g., xDSL, T1/E1). For multi-channel systems, cumulative parasitic capacitance can degrade crosstalk and rise/fall times. To mitigate, isolate the P3206UCLRP behind series current-limiting resistors or use it only on primary protection stages, not directly on high-speed data lines. Consider splitting protection functions: use low-capacitance TVS diodes (<5pF) for signal lines and reserve the P3206UCLRP for power or low-speed interface rails where crowbar action is acceptable. Always verify eye diagram margins post-layout with the device installed.
FAQ Icon

What are the PCB layout best practices when integrating the P3206UCLRP in surface-mount surge protec

To safely route 400A 8/20µs surge currents in the P3206UCLRP, use wide, short traces (>2mm width or filled polygons) with minimal inductance between the device and threat entry point (e.g., connector). Avoid sharp bends; use curved or mitered corners. Connect the device to a robust ground plane using multiple vias near the pins to reduce thermal and mechanical stress. Place the P3206UCLRP at the point of entry, before any filtering or protection stages, to prevent energy from propagating inward. Use thermal relief pads only if necessary for assembly, but minimize them to maintain heat dissipation. Simulate current density in layout tools to avoid hotspots under repeated surge events.
FAQ Icon

What reliability risks should be considered when using the P3206UCLRP in industrial environments pro

The P3206UCLRP is rated for 100A peak pulse current under 10/1000µs waveform, so operation near 75A repeatedly pushes it close to its limit. Industrial environments with frequent surges risk cumulative degradation due to thermal stress, even if individual events are within spec. Ensure the device has adequate PCB copper for heat dissipation and monitor junction temperature rise. Implement upstream coordination—use gas discharge tubes (GDTs) or series impedance to shunt bulk energy, reserving the P3206UCLRP for residual protection. Verify performance over lifecycle testing simulating real-world surge frequency. Also, validate that the 150mA hold current can be reliably interrupted by the system’s power circuitry to ensure turn-off after triggering.

Quality Assurance (QC)

WINSURE ensures the quality and authenticity of every electronic component through professional inspections and batch sampling, guaranteeing reliable sourcing, stable performance, and compliance with technical specifications, helping customers reduce supply chain risks and confidently use components in production.

Quality Assurance
Counterfeit and defect prevention

Counterfeit and defect prevention

Visual and packaging inspection

Electrical performance verification

Electrical performance verification

Life and reliability evaluation

Life and reliability evaluation

WINSURE Certification
ISO 209001_2015
ISO 209001_2015
ISO 14001_2015
ISO 2014001_2015
ISO 45001_2018
ISO 2045001_2018
DUNS REGISTERED
DUNS REGISTERED
Companines Registry
Companines Registry
ASA Certificate
ASA Certificate
UKAS
UKAS
ESD Certificate
ESD Certificate
Blogs & Posts
whatsapp-icons Chat online
RFQ List ({0} Items)

You can add multiple products here.

  • It is empty.
del Clear All Products
Compare List ({0} Items)

You can add multiple products here.

  • It is empty.
del Clear All Products