0.0 / 5.0 - (0 Ratings)

LC4256ZE-5TN144C

Electronics Part Number

LC4256ZE-5TN144C-WX
LC4256ZE-5TN144C

Description

CPLD, 256 Macrocells, 5.8ns, 144-TQFP

Inventory

213 Pcs New Original In Stock
"Embedded ICs: compact, reliable, high-performance. Integrated functionality reduces BOM cost. For consumer and industrial electronics.",
Quantity
Minimum 1

Purchase and inquiry

Quality Assurance

365 - Day Quality Guarantee - Every part fully backed.

90 - Day Refund or Exchange - Defective parts? No hassle.

Limited Stock, Order Now - Get reliable parts without worry.

Global Shipping & Secure Packaging

Worldwide Delivery in 3-5 Business Days

100% ESD Anti-Static Packaging

Real-Time Tracking for Every Order

Secure & Flexible Payment

Credit Card, VISA, MasterCard, PayPal, Western Union, Telegraphic Transfer(T/T) and more

All payments encrypted for security

RFQ (Request for Quotations)

Submit your RFQ directly on the product detail page or the RFQ page.

Our sales team will respond within 24 hours.

Payment method

PayPal (recommended for new customers)

Credit Cards

Wire Transfer (T/T) – Available in USD, EUR, HKD, and other currencies.

Important Notice

You'll receive a confirmation email after submitting an RFQ.

Didn't get it? Check your spam folder and whitelist Info@WINSURE-Electronics.com

Prices and stock may change; we'll reconfirm your order.

Questions? Contact us anytime.

Freight

Basic cost: USD 70.00

Actual cost may vary depending on weight and destination

Shipping method

Shipped from Hong Kong via FedEx/DHL/UPS/TNT

Delivery Time

In-stock items: Ready to ship in 1-2 days

Transit time: 3-5 business days (FedEx/DHL/UPS)

Special requests? Contact us: Info@WINSURE-Electronics.com

Request Quote (Ships tomorrow)
*Quantity
Minimum 1
num_del num_add
(*) (*) is mandatory
We'll get back to you within 24 hours

Technical Specifications

Category Interface, Modems - ICs and Modules

Manufacturer Skyworks Solutions

Packaging Tube

Mounting Type Surface Mount

Package / Case 16-SOIC (0.154", 3.90mm Width)

Series -

Base Product Number SI2434

Product Status Obsolete

Voltage - Supply 3.3V

Supplier Device Package 16-SOIC

Data Format V.34

Baud Rates -

Data Sheet Document (D)

Datasheets Download SI2434-C-FS Product Specification (PDF)

HTML Datasheet SI2434-C-FS-DG

Environmental & Export Classification

Moisture Sensitivity Level (MSL) 3 (168 Hours)

ECCN 5A991B2

HTSUS 8542.39.0001

Additional Information

Other Names -SI2434-C

Standard Package 48

Reviews

0.0/5.0-(Show up to 5 Ratings)
No reviews yet
Publish Evalution
* Product Rating
(Normal/Preferably/Outstanding, default 5 stars)
★★★★★
★★★★★
*Evalution Message
Please enter your review message.
Please post honest comments and do not post ilegal comments.

Frequently Asked Questions (FAQ)

FAQ Icon

What are the key design-in risks when using the SI2434-C-FS in a new product given its obsolete stat

Using the SI2434-C-FS in new designs carries significant supply chain and long-term reliability risks due to its obsolete status. While 2100 units are available as new original stock, future availability is not guaranteed, which can disrupt production and end-of-life planning. Engineers should evaluate last-time buy options and prioritize redesigning with active parts like the SI2434-D-FS or alternative V.34 modems. If proceeding, implement strict inventory buffering and consider conformal coating or protective packaging to extend field life, especially in harsh environments.
FAQ Icon

Can the SI2434-C-FS be used as a drop-in replacement for the SI2434-D-FS, and what compatibility iss

The SI2434-C-FS is not a guaranteed drop-in replacement for the SI2434-D-FS despite similar functionality and package (16-SOIC). Differences in firmware, voltage tolerance, or internal register mapping may exist due to revisions between variants. Designers must verify timing, power sequencing, and control signal levels match datasheet requirements for each variant. Always perform interoperability testing with connected host processors and line drivers. Prioritize reviewing Skyworks' revision notes or contacting authorized distributors for cross-reference guidance before substitution.
FAQ Icon

How does the 3.3V supply constraint of the SI2434-C-FS affect integration with legacy 5V microcontro

The SI2434-C-FS operates strictly at 3.3V, creating level-shifting challenges when interfacing with 5V microcontrollers or legacy UART peripherals. Direct connection risks damage or unreliable communication. Use bidirectional level shifters (e.g., TXS0108E) or series resistors with clamping diodes on control and data lines to prevent overvoltage. Ensure signal rise/fall times remain within acceptable limits after translation to maintain reliable modem handshaking and V.34 data integrity.
FAQ Icon

What thermal and PCB layout considerations are critical for reliable SI2434-C-FS performance in high

For reliable operation of the SI2434-C-FS in high-density designs, maintain adequate copper pour for thermal dissipation and follow MSL 3 handling guidelines with a 168-hour floor life. Use thermal relief on ground pins and ensure uniform solder stencil apertures to avoid tombstoning. Keep analog signal paths (e.g., line driver outputs) short and away from high-speed digital traces to minimize noise coupling. Stagger reflow profiles to avoid thermal shock, especially given the component's obsolete status and potential aging from long-term storage.
FAQ Icon

What are the reliability implications of using SI2434-C-FS in industrial environments with extended

The SI2434-C-FS, packaged in 16-SOIC, lacks extended temperature or hermetic sealing, making it vulnerable in harsh industrial environments. Its MSL 3 rating indicates sensitivity to moisture during assembly, necessitating controlled storage and reflow within 168 hours of exposure. Post-assembly, conformal coating or potting is recommended to mitigate corrosion and thermal cycling fatigue. Monitor field failure rates closely, especially if operating near ambient extremes, and design in redundancy or remote diagnostics due to unavailability of long-term replacement options.
FAQ Icon

What are the key design-in risks when using the SI2434-C-FS in a new product given its obsolete stat

Using the SI2434-C-FS in new designs carries significant supply chain and long-term reliability risks due to its obsolete status. While 2100 units are available as new original stock, future availability is not guaranteed, which can disrupt production and end-of-life planning. Engineers should evaluate last-time buy options and prioritize redesigning with active parts like the SI2434-D-FS or alternative V.34 modems. If proceeding, implement strict inventory buffering and consider conformal coating or protective packaging to extend field life, especially in harsh environments.
FAQ Icon

Can the SI2434-C-FS be used as a drop-in replacement for the SI2434-D-FS, and what compatibility iss

The SI2434-C-FS is not a guaranteed drop-in replacement for the SI2434-D-FS despite similar functionality and package (16-SOIC). Differences in firmware, voltage tolerance, or internal register mapping may exist due to revisions between variants. Designers must verify timing, power sequencing, and control signal levels match datasheet requirements for each variant. Always perform interoperability testing with connected host processors and line drivers. Prioritize reviewing Skyworks' revision notes or contacting authorized distributors for cross-reference guidance before substitution.
FAQ Icon

How does the 3.3V supply constraint of the SI2434-C-FS affect integration with legacy 5V microcontro

The SI2434-C-FS operates strictly at 3.3V, creating level-shifting challenges when interfacing with 5V microcontrollers or legacy UART peripherals. Direct connection risks damage or unreliable communication. Use bidirectional level shifters (e.g., TXS0108E) or series resistors with clamping diodes on control and data lines to prevent overvoltage. Ensure signal rise/fall times remain within acceptable limits after translation to maintain reliable modem handshaking and V.34 data integrity.
FAQ Icon

What thermal and PCB layout considerations are critical for reliable SI2434-C-FS performance in high

For reliable operation of the SI2434-C-FS in high-density designs, maintain adequate copper pour for thermal dissipation and follow MSL 3 handling guidelines with a 168-hour floor life. Use thermal relief on ground pins and ensure uniform solder stencil apertures to avoid tombstoning. Keep analog signal paths (e.g., line driver outputs) short and away from high-speed digital traces to minimize noise coupling. Stagger reflow profiles to avoid thermal shock, especially given the component's obsolete status and potential aging from long-term storage.
FAQ Icon

What are the reliability implications of using SI2434-C-FS in industrial environments with extended

The SI2434-C-FS, packaged in 16-SOIC, lacks extended temperature or hermetic sealing, making it vulnerable in harsh industrial environments. Its MSL 3 rating indicates sensitivity to moisture during assembly, necessitating controlled storage and reflow within 168 hours of exposure. Post-assembly, conformal coating or potting is recommended to mitigate corrosion and thermal cycling fatigue. Monitor field failure rates closely, especially if operating near ambient extremes, and design in redundancy or remote diagnostics due to unavailability of long-term replacement options.

Quality Assurance (QC)

WINSURE ensures the quality and authenticity of every electronic component through professional inspections and batch sampling, guaranteeing reliable sourcing, stable performance, and compliance with technical specifications, helping customers reduce supply chain risks and confidently use components in production.

Quality Assurance
Counterfeit and defect prevention

Counterfeit and defect prevention

Visual and packaging inspection

Electrical performance verification

Electrical performance verification

Life and reliability evaluation

Life and reliability evaluation

WINSURE Certification
ISO 209001_2015
ISO 209001_2015
ISO 14001_2015
ISO 2014001_2015
ISO 45001_2018
ISO 2045001_2018
DUNS REGISTERED
DUNS REGISTERED
Companines Registry
Companines Registry
ASA Certificate
ASA Certificate
UKAS
UKAS
ESD Certificate
ESD Certificate
Blogs & Posts
whatsapp-icons Chat online
RFQ List ({0} Items)

You can add multiple products here.

  • It is empty.
del Clear All Products
Compare List ({0} Items)

You can add multiple products here.

  • It is empty.
del Clear All Products