0.0 / 5.0 - (0 Ratings)

G16-A-0315-85-050

Electronics Part Number

G16-A-0315-85-050-WX
G16-A-0315-85-050

Description

Disc-shaped Magnet, 1.005" x 0.210"

Inventory

431 Pcs New Original In Stock
Neobond permanent magnet, 25.53mm diameter x 5.33mm, delivering consistent magnetic force for sensor applications and magnetic assemblies.
Quantity
Minimum 1

Purchase and inquiry

Quality Assurance

365 - Day Quality Guarantee - Every part fully backed.

90 - Day Refund or Exchange - Defective parts? No hassle.

Limited Stock, Order Now - Get reliable parts without worry.

Global Shipping & Secure Packaging

Worldwide Delivery in 3-5 Business Days

100% ESD Anti-Static Packaging

Real-Time Tracking for Every Order

Secure & Flexible Payment

Credit Card, VISA, MasterCard, PayPal, Western Union, Telegraphic Transfer(T/T) and more

All payments encrypted for security

RFQ (Request for Quotations)

Submit your RFQ directly on the product detail page or the RFQ page.

Our sales team will respond within 24 hours.

Payment method

PayPal (recommended for new customers)

Credit Cards

Wire Transfer (T/T) – Available in USD, EUR, HKD, and other currencies.

Important Notice

You'll receive a confirmation email after submitting an RFQ.

Didn't get it? Check your spam folder and whitelist Info@WINSURE-Electronics.com

Prices and stock may change; we'll reconfirm your order.

Questions? Contact us anytime.

Freight

Basic cost: USD 70.00

Actual cost may vary depending on weight and destination

Shipping method

Shipped from Hong Kong via FedEx/DHL/UPS/TNT

Delivery Time

In-stock items: Ready to ship in 1-2 days

Transit time: 3-5 business days (FedEx/DHL/UPS)

Special requests? Contact us: Info@WINSURE-Electronics.com

Request Quote (Ships tomorrow)
*Quantity
Minimum 1
num_del num_add
(*) (*) is mandatory
We'll get back to you within 24 hours

Technical Specifications

Category Motion Sensors, IMUs (Inertial Measurement Units)

Manufacturer STMicroelectronics

Packaging -

Operating Temperature -40°C ~ 85°C (TA)

Mounting Type Surface Mount

Package / Case 28-VFLGA Module

Series -

Base Product Number LSM303

Sensor Type Accelerometer, Magnetometer, 6 Axis

Product Status Obsolete

Output Type I2C

Supplier Device Package 28-LGA (5x5)

Data Sheet Document (D)

Datasheets Download LSM303DLM Product Specification (PDF)

HTML Datasheet LSM303DLM-DG

Environmental & Export Classification

RoHS Status ROHS3 Compliant

Moisture Sensitivity Level (MSL) 1 (Unlimited)

REACH Status REACH Unaffected

ECCN EAR99

HTSUS 8542.39.0001

Additional Information

Standard Package 490

Reviews

0.0/5.0-(Show up to 5 Ratings)
No reviews yet
Publish Evalution
* Product Rating
(Normal/Preferably/Outstanding, default 5 stars)
★★★★★
★★★★★
*Evalution Message
Please enter your review message.
Please post honest comments and do not post ilegal comments.

Frequently Asked Questions (FAQ)

FAQ Icon

Can the LSM303DLM be used as a drop-in replacement for the LSM303DLHC in an existing I2C-based navig

The LSM303DLM is not a direct drop-in replacement for the LSM303DLHC due to differences in register maps, sensitivity ranges, and internal calibration algorithms—despite sharing the same 6-axis IMU functionality and I2C interface. While both are surface-mount 28-LGA devices from STMicroelectronics, the LSM303DLM has a different magnetometer full-scale range (±2 to ±8 gauss vs. ±1.3 to ±8 gauss on the DLHC) and distinct register addresses for configuration and data output. Firmware must be updated to reflect correct register mappings and scaling factors. Additionally, magnetic calibration routines may need recalibration due to sensor response variations. Always validate timing compatibility and pull-up resistor values on the I2C lines, as subtle electrical differences can affect communication stability at higher clock speeds.
FAQ Icon

What are the key reliability risks when designing with the LSM303DLM in a high-vibration industrial

The LSM303DLM’s obsolete status increases long-term reliability risks, especially in high-vibration applications where mechanical stress can exacerbate solder joint fatigue on the 28-LGA package. With no new stock expected beyond current inventory (1550 pcs), supply chain discontinuity could force last-time buys or redesigns. To mitigate, implement robust PCB pad design with proper NSMD (non-solder mask defined) layout, use underfill if feasible, and conduct accelerated life testing under thermal cycling and vibration profiles matching your application. Consider adding redundant sensing or migrating to a supported successor like the LSM303AGR, which offers pin-compatible migration paths and improved shock resistance. Always derate operating temperature and avoid exceeding the -40°C to 85°C TA range to extend mean time between failures.
FAQ Icon

How does the LSM303DLM compare to the Bosch BMX055 in terms of power consumption, noise performance,

For battery-powered eCompass designs, the LSM303DLM typically consumes more power in active mode (~100 µA combined) compared to the BMX055 (~50 µA in low-power mode), making the latter more suitable for ultra-low-power applications. However, the LSM303DLM offers better noise density on the magnetometer (≈0.3 mg/√Hz vs. ≈0.5 mg/√Hz on BMX055), which can improve heading accuracy in magnetically clean environments. Integration complexity favors the LSM303DLM due to its simpler I2C-only interface and unified 6-axis output, whereas the BMX055 requires managing three separate dies (accel, gyro, mag) with potential synchronization challenges. If your design prioritizes accuracy over power budget and you’re already committed to STMicroelectronics’ ecosystem, the LSM303DLM remains viable—but factor in its obsolete status when planning long-term production.
FAQ Icon

What design constraints should I consider when replacing the LSM303DLM with the LSM6DSL in a space-c

Replacing the LSM303DLM with the LSM6DSL is not functionally feasible because the LSM6DSL is a 6-axis IMU (accelerometer + gyroscope) and lacks a magnetometer—the LSM303DLM includes both an accelerometer and magnetometer. To achieve equivalent functionality, you would need to pair the LSM6DSL with a separate magnetometer such as the LIS3MDL, increasing BOM count, PCB area, and firmware complexity. While the LSM6DSL offers lower power and better performance than the LSM303DLM’s accelerometer, the added integration effort and lack of monolithic 6-axis magnetic sensing make this substitution impractical for compact wearables unless you can eliminate magnetometer requirements. Instead, consider the LSM303AGR, which is a modern, non-obsolete alternative with similar footprint and full accelerometer/magnetometer integration.
FAQ Icon

Given that the LSM303DLM is obsolete, what are the best practices for qualifying a second-source or

When qualifying a second-source alternative to the obsolete LSM303DLM—such as the LSM303AGR or Adafruit’s based modules using similar ST sensors—focus on three critical areas: I2C electrical compatibility, mechanical footprint alignment, and magnetic response consistency. First, verify that the replacement device supports identical I2C clock stretching behavior and input capacitance to avoid timing violations on shared buses. Second, confirm the 28-LGA (5x5 mm) package dimensions and pad layout match to prevent PCB re-spins. Third, conduct comparative magnetic field mapping tests across multiple units and orientations to ensure heading accuracy remains within acceptable tolerances, as even minor sensitivity or offset differences can degrade eCompass performance. Always perform system-level validation under real-world conditions (e.g., near motors or ferrous materials) and update calibration algorithms if necessary. Document all deviations and maintain a risk-mitigation plan for end-of-life scenarios.
FAQ Icon

Can the LSM303DLM be used as a drop-in replacement for the LSM303DLHC in an existing I2C-based navig

The LSM303DLM is not a direct drop-in replacement for the LSM303DLHC due to differences in register maps, sensitivity ranges, and internal calibration algorithms—despite sharing the same 6-axis IMU functionality and I2C interface. While both are surface-mount 28-LGA devices from STMicroelectronics, the LSM303DLM has a different magnetometer full-scale range (±2 to ±8 gauss vs. ±1.3 to ±8 gauss on the DLHC) and distinct register addresses for configuration and data output. Firmware must be updated to reflect correct register mappings and scaling factors. Additionally, magnetic calibration routines may need recalibration due to sensor response variations. Always validate timing compatibility and pull-up resistor values on the I2C lines, as subtle electrical differences can affect communication stability at higher clock speeds.
FAQ Icon

What are the key reliability risks when designing with the LSM303DLM in a high-vibration industrial

The LSM303DLM’s obsolete status increases long-term reliability risks, especially in high-vibration applications where mechanical stress can exacerbate solder joint fatigue on the 28-LGA package. With no new stock expected beyond current inventory (1550 pcs), supply chain discontinuity could force last-time buys or redesigns. To mitigate, implement robust PCB pad design with proper NSMD (non-solder mask defined) layout, use underfill if feasible, and conduct accelerated life testing under thermal cycling and vibration profiles matching your application. Consider adding redundant sensing or migrating to a supported successor like the LSM303AGR, which offers pin-compatible migration paths and improved shock resistance. Always derate operating temperature and avoid exceeding the -40°C to 85°C TA range to extend mean time between failures.
FAQ Icon

How does the LSM303DLM compare to the Bosch BMX055 in terms of power consumption, noise performance,

For battery-powered eCompass designs, the LSM303DLM typically consumes more power in active mode (~100 µA combined) compared to the BMX055 (~50 µA in low-power mode), making the latter more suitable for ultra-low-power applications. However, the LSM303DLM offers better noise density on the magnetometer (≈0.3 mg/√Hz vs. ≈0.5 mg/√Hz on BMX055), which can improve heading accuracy in magnetically clean environments. Integration complexity favors the LSM303DLM due to its simpler I2C-only interface and unified 6-axis output, whereas the BMX055 requires managing three separate dies (accel, gyro, mag) with potential synchronization challenges. If your design prioritizes accuracy over power budget and you’re already committed to STMicroelectronics’ ecosystem, the LSM303DLM remains viable—but factor in its obsolete status when planning long-term production.
FAQ Icon

What design constraints should I consider when replacing the LSM303DLM with the LSM6DSL in a space-c

Replacing the LSM303DLM with the LSM6DSL is not functionally feasible because the LSM6DSL is a 6-axis IMU (accelerometer + gyroscope) and lacks a magnetometer—the LSM303DLM includes both an accelerometer and magnetometer. To achieve equivalent functionality, you would need to pair the LSM6DSL with a separate magnetometer such as the LIS3MDL, increasing BOM count, PCB area, and firmware complexity. While the LSM6DSL offers lower power and better performance than the LSM303DLM’s accelerometer, the added integration effort and lack of monolithic 6-axis magnetic sensing make this substitution impractical for compact wearables unless you can eliminate magnetometer requirements. Instead, consider the LSM303AGR, which is a modern, non-obsolete alternative with similar footprint and full accelerometer/magnetometer integration.
FAQ Icon

Given that the LSM303DLM is obsolete, what are the best practices for qualifying a second-source or

When qualifying a second-source alternative to the obsolete LSM303DLM—such as the LSM303AGR or Adafruit’s based modules using similar ST sensors—focus on three critical areas: I2C electrical compatibility, mechanical footprint alignment, and magnetic response consistency. First, verify that the replacement device supports identical I2C clock stretching behavior and input capacitance to avoid timing violations on shared buses. Second, confirm the 28-LGA (5x5 mm) package dimensions and pad layout match to prevent PCB re-spins. Third, conduct comparative magnetic field mapping tests across multiple units and orientations to ensure heading accuracy remains within acceptable tolerances, as even minor sensitivity or offset differences can degrade eCompass performance. Always perform system-level validation under real-world conditions (e.g., near motors or ferrous materials) and update calibration algorithms if necessary. Document all deviations and maintain a risk-mitigation plan for end-of-life scenarios.

Quality Assurance (QC)

WINSURE ensures the quality and authenticity of every electronic component through professional inspections and batch sampling, guaranteeing reliable sourcing, stable performance, and compliance with technical specifications, helping customers reduce supply chain risks and confidently use components in production.

Quality Assurance
Counterfeit and defect prevention

Counterfeit and defect prevention

Visual and packaging inspection

Electrical performance verification

Electrical performance verification

Life and reliability evaluation

Life and reliability evaluation

WINSURE Certification
ISO 209001_2015
ISO 209001_2015
ISO 14001_2015
ISO 2014001_2015
ISO 45001_2018
ISO 2045001_2018
DUNS REGISTERED
DUNS REGISTERED
Companines Registry
Companines Registry
ASA Certificate
ASA Certificate
UKAS
UKAS
ESD Certificate
ESD Certificate
Blogs & Posts
whatsapp-icons Chat online
RFQ List ({0} Items)

You can add multiple products here.

  • It is empty.
del Clear All Products
Compare List ({0} Items)

You can add multiple products here.

  • It is empty.
del Clear All Products