0.0 / 5.0 - (0 Ratings)

502-6504-10

Electronics Part Number

502-6504-10-WX
502-6504-10

Description

LS-6504-10 relay, 10A, for auto systems

Inventory

910 Pcs New Original In Stock
Short-arc xenon lamp; metal can; 11–28V; crisp focused beam; stable output; for endoscopes and analytical equipment.
Quantity
Minimum 1

Purchase and inquiry

Quality Assurance

365 - Day Quality Guarantee - Every part fully backed.

90 - Day Refund or Exchange - Defective parts? No hassle.

Limited Stock, Order Now - Get reliable parts without worry.

Global Shipping & Secure Packaging

Worldwide Delivery in 3-5 Business Days

100% ESD Anti-Static Packaging

Real-Time Tracking for Every Order

Secure & Flexible Payment

Credit Card, VISA, MasterCard, PayPal, Western Union, Telegraphic Transfer(T/T) and more

All payments encrypted for security

RFQ (Request for Quotations)

Submit your RFQ directly on the product detail page or the RFQ page.

Our sales team will respond within 24 hours.

Payment method

PayPal (recommended for new customers)

Credit Cards

Wire Transfer (T/T) – Available in USD, EUR, HKD, and other currencies.

Important Notice

You'll receive a confirmation email after submitting an RFQ.

Didn't get it? Check your spam folder and whitelist Info@WINSURE-Electronics.com

Prices and stock may change; we'll reconfirm your order.

Questions? Contact us anytime.

Freight

Basic cost: USD 70.00

Actual cost may vary depending on weight and destination

Shipping method

Shipped from Hong Kong via FedEx/DHL/UPS/TNT

Delivery Time

In-stock items: Ready to ship in 1-2 days

Transit time: 3-5 business days (FedEx/DHL/UPS)

Special requests? Contact us: Info@WINSURE-Electronics.com

Request Quote (Ships tomorrow)
*Quantity
Minimum 1
num_del num_add
(*) (*) is mandatory
We'll get back to you within 24 hours

Technical Specifications

Category I/O Relay Modules

Manufacturer Sensata Technologies

Packaging Tray

Color White

Series IDC

Features Hold Down Screw

Product Status Active

Type DC Input Module

Style Standard

Voltage - Output 5VDC

Voltage - Input 24VDC

Current - Input 34 mA

Current - Output 16mA

Turn On Time 1ms

Turn Off Time 1ms

Data Sheet Document (D)

Datasheets Download IDC5 Product Specification (PDF)

HTML Datasheet IDC5-DG

Environmental & Export Classification

RoHS Status ROHS3 Compliant

Moisture Sensitivity Level (MSL) Not Applicable

REACH Status REACH Unaffected

ECCN EAR99

HTSUS 8536.41.0030

Additional Information

Other Names 2266-IDC5 IDC5INACTIVE CC1202-NDR IDC-5 IDC5 INACTIVE-DG CC1202 IDC5-DG

Standard Package 25

Reviews

0.0/5.0-(Show up to 5 Ratings)
No reviews yet
Publish Evalution
* Product Rating
(Normal/Preferably/Outstanding, default 5 stars)
★★★★★
★★★★★
*Evalution Message
Please enter your review message.
Please post honest comments and do not post ilegal comments.

Frequently Asked Questions (FAQ)

FAQ Icon

What are the key design-in considerations when integrating the Sensata-Crydom IDC5 DC input module i

When integrating the Sensata-Crydom IDC5 into a PLC system with noisy 24VDC supplies, ensure input filtering using a parallel 100nF ceramic capacitor and 10µF electrolytic capacitor at the module’s power pins to prevent false triggering. The IDC5 has no onboard EMI filtering, so external transient protection (like a TVS diode) is recommended in environments with frequent inductive load switching. Maintain trace separation from high-voltage circuits to avoid coupling, and use shielded cables for input signals to maintain signal integrity given the 16mA sensing threshold sensitivity.
FAQ Icon

Can the Sensata-Crydom IDC5 safely replace competing input modules like the Allen-Bradley 1746-IB16

The Sensata-Crydom IDC5 is not a direct replacement for full PLC I/O cards like the Allen-Bradley 1746-IB16 or Siemens 6ES7132-4BB01-0AA0, as it functions as a discrete DC input interface module rather than a rack-mounted I/O card. However, it can be used as a field-level signal conditioner. Key risks include mismatched input leakage currents and voltage thresholds—verify that your source can supply the IDC5’s 34mA input requirement, unlike the higher-impedance inputs of those PLC modules. Also confirm mechanical fit and hold-down screw compatibility, as the IDC5 uses M3 hardware for mounting.
FAQ Icon

How does the 1ms turn-on and turn-off time of the IDC5 impact its use in high-speed sensing applicat

The 1ms response time of the Sensata-Crydom IDC5 limits its effectiveness in high-speed applications requiring sub-millisecond signal processing, such as real-time encoder feedback or rapid sequence control. While sufficient for standard pushbuttons, limit switches, or slow-varying process signals, using the IDC5 in high-speed contexts may result in missed or delayed transitions. For such cases, consider buffered digital input modules with <100µs response. If ADC integration is needed, ensure your controller’s scan rate exceeds 2kHz to avoid aliasing due to the IDC5’s propagation delay.
FAQ Icon

What are the reliability concerns when using the Sensata-Crydom IDC5 in high-vibration industrial en

In high-vibration environments, connector loosening or PCB pad stress can compromise the reliability of the Sensata-Crydom IDC5. Its integrated hold-down screw feature allows secure mechanical mounting to prevent movement-induced solder joint fatigue. Use a nylon-insert lock nut or threadlocker on the M3 screw to maintain clamping force under continuous vibration. Additionally, avoid rigid wiring—use strain relief and flexible leads to decouple mechanical stress from the module terminals, reducing long-term failure risks in mobile or heavy machinery applications.
FAQ Icon

How should engineers handle supply voltage tolerances when using the IDC5 with 24VDC systems that fr

The Sensata-Crydom IDC5 is rated for 24VDC input, but does not specify a lower voltage threshold in public documentation. Operating below 22V may lead to unreliable switching or failure to activate, especially during system inrush. To mitigate, verify actual minimum supply voltage under load—ensure it stays above 20VDC during brownout conditions. Use regulated power supplies with sufficient headroom or add a local boost converter if voltage droop exceeds 15%. Monitoring supply voltage with a diagnostic circuit upstream of the IDC5 can prevent undervoltage-induced misoperation in critical control loops.
FAQ Icon

What are the key design-in considerations when integrating the Sensata-Crydom IDC5 DC input module i

When integrating the Sensata-Crydom IDC5 into a PLC system with noisy 24VDC supplies, ensure input filtering using a parallel 100nF ceramic capacitor and 10µF electrolytic capacitor at the module’s power pins to prevent false triggering. The IDC5 has no onboard EMI filtering, so external transient protection (like a TVS diode) is recommended in environments with frequent inductive load switching. Maintain trace separation from high-voltage circuits to avoid coupling, and use shielded cables for input signals to maintain signal integrity given the 16mA sensing threshold sensitivity.
FAQ Icon

Can the Sensata-Crydom IDC5 safely replace competing input modules like the Allen-Bradley 1746-IB16

The Sensata-Crydom IDC5 is not a direct replacement for full PLC I/O cards like the Allen-Bradley 1746-IB16 or Siemens 6ES7132-4BB01-0AA0, as it functions as a discrete DC input interface module rather than a rack-mounted I/O card. However, it can be used as a field-level signal conditioner. Key risks include mismatched input leakage currents and voltage thresholds—verify that your source can supply the IDC5’s 34mA input requirement, unlike the higher-impedance inputs of those PLC modules. Also confirm mechanical fit and hold-down screw compatibility, as the IDC5 uses M3 hardware for mounting.
FAQ Icon

How does the 1ms turn-on and turn-off time of the IDC5 impact its use in high-speed sensing applicat

The 1ms response time of the Sensata-Crydom IDC5 limits its effectiveness in high-speed applications requiring sub-millisecond signal processing, such as real-time encoder feedback or rapid sequence control. While sufficient for standard pushbuttons, limit switches, or slow-varying process signals, using the IDC5 in high-speed contexts may result in missed or delayed transitions. For such cases, consider buffered digital input modules with <100µs response. If ADC integration is needed, ensure your controller’s scan rate exceeds 2kHz to avoid aliasing due to the IDC5’s propagation delay.
FAQ Icon

What are the reliability concerns when using the Sensata-Crydom IDC5 in high-vibration industrial en

In high-vibration environments, connector loosening or PCB pad stress can compromise the reliability of the Sensata-Crydom IDC5. Its integrated hold-down screw feature allows secure mechanical mounting to prevent movement-induced solder joint fatigue. Use a nylon-insert lock nut or threadlocker on the M3 screw to maintain clamping force under continuous vibration. Additionally, avoid rigid wiring—use strain relief and flexible leads to decouple mechanical stress from the module terminals, reducing long-term failure risks in mobile or heavy machinery applications.
FAQ Icon

How should engineers handle supply voltage tolerances when using the IDC5 with 24VDC systems that fr

The Sensata-Crydom IDC5 is rated for 24VDC input, but does not specify a lower voltage threshold in public documentation. Operating below 22V may lead to unreliable switching or failure to activate, especially during system inrush. To mitigate, verify actual minimum supply voltage under load—ensure it stays above 20VDC during brownout conditions. Use regulated power supplies with sufficient headroom or add a local boost converter if voltage droop exceeds 15%. Monitoring supply voltage with a diagnostic circuit upstream of the IDC5 can prevent undervoltage-induced misoperation in critical control loops.

Quality Assurance (QC)

WINSURE ensures the quality and authenticity of every electronic component through professional inspections and batch sampling, guaranteeing reliable sourcing, stable performance, and compliance with technical specifications, helping customers reduce supply chain risks and confidently use components in production.

Quality Assurance
Counterfeit and defect prevention

Counterfeit and defect prevention

Visual and packaging inspection

Electrical performance verification

Electrical performance verification

Life and reliability evaluation

Life and reliability evaluation

WINSURE Certification
ISO 209001_2015
ISO 209001_2015
ISO 14001_2015
ISO 2014001_2015
ISO 45001_2018
ISO 2045001_2018
DUNS REGISTERED
DUNS REGISTERED
Companines Registry
Companines Registry
ASA Certificate
ASA Certificate
UKAS
UKAS
ESD Certificate
ESD Certificate
Blogs & Posts
whatsapp-icons Chat online
RFQ List ({0} Items)

You can add multiple products here.

  • It is empty.