Description

10pF 50V Thin Film Capacitor, 0603 SMD RF

Inventory

54 Pcs New Original In Stock
0603 surface-mount thin film capacitor. 10pF, 50V. Precise capacitance, low drift. Ideal for high-frequency tuning and precision timing.
Quantity
Minimum 1

Purchase and inquiry

Quality Assurance

365 - Day Quality Guarantee - Every part fully backed.

90 - Day Refund or Exchange - Defective parts? No hassle.

Limited Stock, Order Now - Get reliable parts without worry.

Global Shipping & Secure Packaging

Worldwide Delivery in 3-5 Business Days

100% ESD Anti-Static Packaging

Real-Time Tracking for Every Order

Secure & Flexible Payment

Credit Card, VISA, MasterCard, PayPal, Western Union, Telegraphic Transfer(T/T) and more

All payments encrypted for security

RFQ (Request for Quotations)

Submit your RFQ directly on the product detail page or the RFQ page.

Our sales team will respond within 24 hours.

Payment method

PayPal (recommended for new customers)

Credit Cards

Wire Transfer (T/T) – Available in USD, EUR, HKD, and other currencies.

Important Notice

You'll receive a confirmation email after submitting an RFQ.

Didn't get it? Check your spam folder and whitelist Info@WINSURE-Electronics.com

Prices and stock may change; we'll reconfirm your order.

Questions? Contact us anytime.

Freight

Basic cost: USD 70.00

Actual cost may vary depending on weight and destination

Shipping method

Shipped from Hong Kong via FedEx/DHL/UPS/TNT

Delivery Time

In-stock items: Ready to ship in 1-2 days

Transit time: 3-5 business days (FedEx/DHL/UPS)

Special requests? Contact us: Info@WINSURE-Electronics.com

Request Quote (Ships tomorrow)
*Quantity
Minimum 1
num_del num_add
(*) (*) is mandatory
We'll get back to you within 24 hours

Technical Specifications

Category Pulse Transformers

Manufacturer Pulse Electronics

Packaging Tape & Reel (TR)

Operating Temperature -40°C ~ 85°C

Mounting Type Surface Mount

Series HX5400NLT

Product Status Active

Size / Dimension 1.120" L x 0.680" W (28.45mm x 17.27mm)

Weight -

Height - Seated (Max) 0.440" (11.18mm)

Inductance 350µH

Transformer Type LAN 1G Base-T, Power over Ethernet (PoE)

ET (Volt-Time) -

Turns Ratio - Primary:Secondary 1CT:1CT

Data Sheet Document (D)

Datasheets Download HX5400NLT Product Specification (PDF)

HTML Datasheet HX5400NLT-DG

Environmental & Export Classification

RoHS Status ROHS3 Compliant

Moisture Sensitivity Level (MSL) 1 (Unlimited)

REACH Status REACH Unaffected

Additional Information

Other Names 553-HX5400NLTTR 553-HX5400NLTCT 553-HX5400NLTDKR

Standard Package 170

Reviews

0.0/5.0-(Show up to 5 Ratings)
No reviews yet
Publish Evalution
* Product Rating
(Normal/Preferably/Outstanding, default 5 stars)
★★★★★
★★★★★
*Evalution Message
Please enter your review message.
Please post honest comments and do not post ilegal comments.

Frequently Asked Questions (FAQ)

FAQ Icon

What are the key design-in risks when using the HX5400NLT in a Power over Ethernet (PoE) application

When designing the HX5400NLT into Power over Ethernet (PoE) systems operating near the upper end of its 85°C temperature range, engineers must account for derating of current handling and potential core saturation under combined data and power loads. The HX5400NLT’s 350µH inductance is stable within spec, but prolonged exposure to high temperature with PoE Type 3 or 4 power levels can accelerate insulation aging. Mitigate risk by ensuring adequate PCB copper pour for thermal dissipation, avoiding enclosed spaces, and validating with thermal imaging under full load. Also confirm that the 1CT:1CT turns ratio maintains signal integrity when PoE DC-DC conversion is downstream.
FAQ Icon

How does the HX5400NLT compare to the Murata 75081111150AG1 in 1G Base-T PoE designs, and can they b

The HX5400NLT and Murata 75081111150AG1 are both quad-channel 1G Base-T PoE transformers with 1CT:1CT ratios and similar footprints, but they differ in shielding and high-frequency response. The HX5400NLT offers superior common-mode rejection above 100MHz due to Pulse Electronics’ optimized winding layout, while the Murata part has tighter channel-to-channel skew. Interchangeability depends on your EMI environment—use the HX5400NLT in noisy industrial settings, but validate signal integrity on the Murata if your design is sensitive to skew. Mechanical compatibility is close but not identical; the HX5400NLT’s 28.45mm x 17.27mm body may require a slight layout adjustment compared to Murata’s version.
FAQ Icon

What are the signal integrity risks when routing differential pairs through the HX5400NLT in a compa

In dense 10-layer switch PCBs, the HX5400NLT’s BGA-style land pattern can introduce impedance discontinuities if vias are routed too close to the pads or if return paths are interrupted across layers. To maintain 100Ω differential impedance through the HX5400NLT, use continuous ground reference planes beneath the transformer, minimize via stubs, and avoid routing unrelated signals under the module due to magnetic coupling risks. Also ensure the 350µH windings do not resonate with excessive trace capacitance—keep traces short and direct between PHY and HX5400NLT. Simulate with IBIS models if operating at near-maximum data rates.
FAQ Icon

Can the HX5400NLT be used reliably in outdoor telecom equipment exposed to wide temperature cycling

Yes, the HX5400NLT is suitable for outdoor telecom deployments due to its -40°C to 85°C operating range and MSL1 (unlimited) moisture sensitivity rating, which supports reflow reliability in humid environments. However, long-term outdoor reliability depends on proper PCB encapsulation—conformal coating is recommended to prevent moisture ingress under the BGA body where condensation could form. Avoid mechanical stress on the HX5400NLT during thermal cycling by using compliant mounting pads and avoiding rigid connectors on the same board section. Monitor for flux residue under the module post-assembly, as it can absorb moisture and cause leakage.
FAQ Icon

What are the failure modes to monitor when replacing a legacy LAN transformer with the HX5400NLT in

When replacing older transformers (e.g., non-PoE-rated 1:1 pulse transformers) with the HX5400NLT in PoE++ (802.3bt) upgrades, the primary risks are insulation breakdown and thermal overload. The HX5400NLT supports PoE but verify that its isolation voltage (implicitly ~1500V per typical Pulse specs) meets safety standards in your region—older designs may not include sufficient creepage. Also, PoE++ currents (up to 960mA per pair) can cause resistive heating in the HX5400NLT’s windings; ensure adjacent components aren’t overheating due to conduction. Use a thermal camera during validation and consider adding a polyfuse if operating near max power. Confirm that the 1CT:1CT ratio doesn’t distort fast Ethernet signaling when DC resistance is loaded.
FAQ Icon

What are the key design-in risks when using the HX5400NLT in a Power over Ethernet (PoE) application

When designing the HX5400NLT into Power over Ethernet (PoE) systems operating near the upper end of its 85°C temperature range, engineers must account for derating of current handling and potential core saturation under combined data and power loads. The HX5400NLT’s 350µH inductance is stable within spec, but prolonged exposure to high temperature with PoE Type 3 or 4 power levels can accelerate insulation aging. Mitigate risk by ensuring adequate PCB copper pour for thermal dissipation, avoiding enclosed spaces, and validating with thermal imaging under full load. Also confirm that the 1CT:1CT turns ratio maintains signal integrity when PoE DC-DC conversion is downstream.
FAQ Icon

How does the HX5400NLT compare to the Murata 75081111150AG1 in 1G Base-T PoE designs, and can they b

The HX5400NLT and Murata 75081111150AG1 are both quad-channel 1G Base-T PoE transformers with 1CT:1CT ratios and similar footprints, but they differ in shielding and high-frequency response. The HX5400NLT offers superior common-mode rejection above 100MHz due to Pulse Electronics’ optimized winding layout, while the Murata part has tighter channel-to-channel skew. Interchangeability depends on your EMI environment—use the HX5400NLT in noisy industrial settings, but validate signal integrity on the Murata if your design is sensitive to skew. Mechanical compatibility is close but not identical; the HX5400NLT’s 28.45mm x 17.27mm body may require a slight layout adjustment compared to Murata’s version.
FAQ Icon

What are the signal integrity risks when routing differential pairs through the HX5400NLT in a compa

In dense 10-layer switch PCBs, the HX5400NLT’s BGA-style land pattern can introduce impedance discontinuities if vias are routed too close to the pads or if return paths are interrupted across layers. To maintain 100Ω differential impedance through the HX5400NLT, use continuous ground reference planes beneath the transformer, minimize via stubs, and avoid routing unrelated signals under the module due to magnetic coupling risks. Also ensure the 350µH windings do not resonate with excessive trace capacitance—keep traces short and direct between PHY and HX5400NLT. Simulate with IBIS models if operating at near-maximum data rates.
FAQ Icon

Can the HX5400NLT be used reliably in outdoor telecom equipment exposed to wide temperature cycling

Yes, the HX5400NLT is suitable for outdoor telecom deployments due to its -40°C to 85°C operating range and MSL1 (unlimited) moisture sensitivity rating, which supports reflow reliability in humid environments. However, long-term outdoor reliability depends on proper PCB encapsulation—conformal coating is recommended to prevent moisture ingress under the BGA body where condensation could form. Avoid mechanical stress on the HX5400NLT during thermal cycling by using compliant mounting pads and avoiding rigid connectors on the same board section. Monitor for flux residue under the module post-assembly, as it can absorb moisture and cause leakage.
FAQ Icon

What are the failure modes to monitor when replacing a legacy LAN transformer with the HX5400NLT in

When replacing older transformers (e.g., non-PoE-rated 1:1 pulse transformers) with the HX5400NLT in PoE++ (802.3bt) upgrades, the primary risks are insulation breakdown and thermal overload. The HX5400NLT supports PoE but verify that its isolation voltage (implicitly ~1500V per typical Pulse specs) meets safety standards in your region—older designs may not include sufficient creepage. Also, PoE++ currents (up to 960mA per pair) can cause resistive heating in the HX5400NLT’s windings; ensure adjacent components aren’t overheating due to conduction. Use a thermal camera during validation and consider adding a polyfuse if operating near max power. Confirm that the 1CT:1CT ratio doesn’t distort fast Ethernet signaling when DC resistance is loaded.

Quality Assurance (QC)

WINSURE ensures the quality and authenticity of every electronic component through professional inspections and batch sampling, guaranteeing reliable sourcing, stable performance, and compliance with technical specifications, helping customers reduce supply chain risks and confidently use components in production.

Quality Assurance
Counterfeit and defect prevention

Counterfeit and defect prevention

Visual and packaging inspection

Electrical performance verification

Electrical performance verification

Life and reliability evaluation

Life and reliability evaluation

WINSURE Certification
ISO 209001_2015
ISO 209001_2015
ISO 14001_2015
ISO 2014001_2015
ISO 45001_2018
ISO 2045001_2018
DUNS REGISTERED
DUNS REGISTERED
Companines Registry
Companines Registry
ASA Certificate
ASA Certificate
UKAS
UKAS
ESD Certificate
ESD Certificate
Blogs & Posts
whatsapp-icons Chat online
RFQ List ({0} Items)

You can add multiple products here.

  • It is empty.
del Clear All Products
Compare List ({0} Items)

You can add multiple products here.

  • It is empty.
del Clear All Products